What was found
INSPECTION TYPE-N/A, NR 3 ENGINE HAD FLAME-OUT AT FL 330. RAN FLAME-OUT CHECKLIST AND RECOVERED ENGINE AT FL 280 IN DESCENT. *S/D* PERFORMED T/S TREE NR 139, PERFORMED ALL ASPECTS OF ADJ/TEST PER MM 71 -00-00, PERFORMED POWER ASSURANCE RUN AND ALL PMC ON AND OFF, CHECK VBV AND VSV RIG TRAVEL CHECK, ALL OPERATES NORMALLY PER MM 71-00-00, FIG 139 PG 169-173.