What was found
INSPECTION TYPE-D, FS 5 RBL 59 FINGER DOUBLER EXFOLIATED ON FWD END APPROX 5 BELOW C/B PANEL AT SUB FLOOR. REMOVED, FABRICATED AND INSTALLED REPLACEMENT PARTS IAW SRM ADDEN 5350-7876, SRM 53-3-3, 51-1-21 AND DWG 5612298-269.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-D, FS 5 RBL 59 FINGER DOUBLER EXFOLIATED ON FWD END APPROX 5 BELOW C/B PANEL AT SUB FLOOR. REMOVED, FABRICATED AND INSTALLED REPLACEMENT PARTS IAW SRM ADDEN 5350-7876, SRM 53-3-3, 51-1-21 AND DWG 5612298-269.