What was found
INSPECTION TYPE:D, STA 270 BETWEEN STR 35R-36 FITTING IS CORRODED (REF N/R 610832 ). REMOVED, FABRICATED, AND INSTALLED REPLACEMENT FITTING IAW SRM 53-2-0, 51-1-20D, 51-3-0, AND DWG 3755822.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:D, STA 270 BETWEEN STR 35R-36 FITTING IS CORRODED (REF N/R 610832 ). REMOVED, FABRICATED, AND INSTALLED REPLACEMENT FITTING IAW SRM 53-2-0, 51-1-20D, 51-3-0, AND DWG 3755822.