What was found
INSPECTION TYPE-D, FLOORBEAMS AND STRUCTURE PLATE BETWEEN FS 1700 AND 1723 LT SIDE HAS CORROSION ON UPPER AND LOWER SURFACES. REMOVED PLATE, FABRICATED, AND INSTALLED REPLACEMENT PLATE IAW SRM 51-1-0 AND 51-1-20. REMOVAL OF LIGHT SURFACE CORROSION WAS WITHIN LIMITS ON THE REST OF SURFACE REF SRM 51-1-8, 53-2-0 FIG 1.