What was found
INSPECTION TYPE-D, RT FLOOR SUPPORT STRUCTURE FROM FS 1440 TO 1540 CORRODED, LWR BILGE. REMOVED, FABRICATED AND INSTALLED REPLACEMENT SUPPORT IAW SRM 53-1-0, 51-9-0, 51-1-20, AND DWG 5753284.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-D, RT FLOOR SUPPORT STRUCTURE FROM FS 1440 TO 1540 CORRODED, LWR BILGE. REMOVED, FABRICATED AND INSTALLED REPLACEMENT SUPPORT IAW SRM 53-1-0, 51-9-0, 51-1-20, AND DWG 5753284.