What was found
INSPECTION TYPE-D, FS 1340 RT SIDE AT FLOOR LEVEL DOOR JAMB TIE ANGLE HAS HEAVY CORROSION. REMOVED, FABRICATED AND INSTALLED DOOR ANGLE IAW SRM 53-4-3, 51-1-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-D, FS 1340 RT SIDE AT FLOOR LEVEL DOOR JAMB TIE ANGLE HAS HEAVY CORROSION. REMOVED, FABRICATED AND INSTALLED DOOR ANGLE IAW SRM 53-4-3, 51-1-21.