What was found
INSPECTION TYPE-D, NR 3 MAIN STA XRS 74.869 STR 51, THE FWD STRINGER SPLICE IS CRACKED IN 3 PLACES. REMOVED AND REPLACED STRINGER SPLICE IAW SRM 51-1-20, 51-3-0, 57-1-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-D, NR 3 MAIN STA XRS 74.869 STR 51, THE FWD STRINGER SPLICE IS CRACKED IN 3 PLACES. REMOVED AND REPLACED STRINGER SPLICE IAW SRM 51-1-20, 51-3-0, 57-1-0.