What was found
INSPECTION TYPE:D, FUSELAGE FRAME F/S 130 HAS NUMEROUS DOUBLE DRILLED, ENLONGATED, AND HOLES WITH SHORT E.D. (CARGO LINER ATTACH HOLES). REMOVED, FABRICATED AND INSTALLED FRAME IAW SRM 51-1-20 AND DHC SK- 894-514 (REF UPS ENRG FILE NR DC8-53-1790).