What was found
INSPECTION TYPE:C, FRAME TIE FITTING AT F/S 120 BETWEEN STRINGERS 31 TO 32L WAS CRACKED. REMOVED, FABRICATED AND INSTALLED FITTING IAW SRM 51-1-21 AND DWG 3751096.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, FRAME TIE FITTING AT F/S 120 BETWEEN STRINGERS 31 TO 32L WAS CRACKED. REMOVED, FABRICATED AND INSTALLED FITTING IAW SRM 51-1-21 AND DWG 3751096.