INSPECTION TYPE:D, C-1 PIT FWD BULKHEAD HORZ FRAME AT FS 70 BL 0, 20 ABOVE LONG 36 HAS BLOWN OUT CORROSION. REMOVED, FABRICATED AND INSTALLED REPLACEMENT FRAME IAW SRM 51-1-21, 51-1-20D, 53-1-0 AND DWG 5613064.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:D, C-1 PIT FWD BULKHEAD HORZ FRAME AT FS 70 BL 0, 20 ABOVE LONG 36 HAS BLOWN OUT CORROSION. REMOVED, FABRICATED AND INSTALLED REPLACEMENT FRAME IAW SRM 51-1-21, 51-1-20D, 53-1-0 AND DWG 5613064.