What was found
INSPECTION TYPE:D, FS 55 RBL 46 FWD SIDE OF FLOORBEAM HAS MODERATE CORROSION UNDER NUT PLATE CHANNEL. ALSO, WEB IS CRACKED. CUT OUT DAMAGED AREA AND INSTALLED REPAIR IAW SRM 53-2-0 FIG 1D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:D, FS 55 RBL 46 FWD SIDE OF FLOORBEAM HAS MODERATE CORROSION UNDER NUT PLATE CHANNEL. ALSO, WEB IS CRACKED. CUT OUT DAMAGED AREA AND INSTALLED REPAIR IAW SRM 53-2-0 FIG 1D.