What was found
INSPECTION TYPE:D F/S 1160 AT LBL 44 ON NR 3 PIT CEILING, FLOORBEAM TANGS HAVE SEVERE CORROSION (METAL IS SEPARATING). REPAIRED IAW DHC SK 809-807.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:D F/S 1160 AT LBL 44 ON NR 3 PIT CEILING, FLOORBEAM TANGS HAVE SEVERE CORROSION (METAL IS SEPARATING). REPAIRED IAW DHC SK 809-807.