What was found
INSPECTION TYPE:D CRACK IN FITTING AT F/S 759 RBL 51 AT THE BEAM SUPPORT WEB. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT FITTING IAW SRM 53-1-0, 51-1-20, DWG 3641125, AND DHC SK-809-663.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:D CRACK IN FITTING AT F/S 759 RBL 51 AT THE BEAM SUPPORT WEB. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT FITTING IAW SRM 53-1-0, 51-1-20, DWG 3641125, AND DHC SK-809-663.