INSPECTION TYPE-D, FLOORBEAM SUPPORT TORQUE BOX FITTING CRACKED FS 1160 AT STR 27R. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT FITTING IAW SRM 51-1-0, 51-1-20D, AND DWG 3754025.