What was found
INSPECTION TYPE-C, FOUND CORROSION ON FRAME FS 70 AT LONGERON 33 LT. REMOVED CORRODED SECTION OF FRAME, FABRICATED NEW FRAME SECTION, SPLICE ANGLES, REPAIR DOUBLER, DRILLED ALL NEW PARTS, TREATED, PRIMED AND INSTALLED IAW DC8 SRM 53-2-5, 51-1-8, 51-1-21, 51-1-20D.