What was found
INSPECTION TYPE-C, F/S 70 BULKHEAD IN NR 1 PIT LT UPPER HORZ INTERCOSTAL IS CRACKED AND CORRODED. REMOVED, FABRICATED AND INSTALLED REPLACEMENT INTERCOSTAL IAW SRM 51-1-21 AND DWG 5613064.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-C, F/S 70 BULKHEAD IN NR 1 PIT LT UPPER HORZ INTERCOSTAL IS CRACKED AND CORRODED. REMOVED, FABRICATED AND INSTALLED REPLACEMENT INTERCOSTAL IAW SRM 51-1-21 AND DWG 5613064.