What was found
INSPECTION TYPE:C DURING C CHECK INSPECTION, FOUND C PIT DOOR T BOLT FITTING CORRODED AT F/S 1194. REMOVED CORRODED FITTING, DRILLED, TREATED, PRIMED AND INSTALLED NEW FITTING IAW DC8 SRM 53-2-0, 51-1-8, 51-1-21, 51-3-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C DURING C CHECK INSPECTION, FOUND C PIT DOOR T BOLT FITTING CORRODED AT F/S 1194. REMOVED CORRODED FITTING, DRILLED, TREATED, PRIMED AND INSTALLED NEW FITTING IAW DC8 SRM 53-2-0, 51-1-8, 51-1-21, 51-3-0.