What was found
INSPECTION TYPE:C DURING C CHECK INSPECTION, FOUND T BOLT FITTING CORRODED F/S 1178 (C PIT DOOR). REMOVED CORRODED FITTING, DRILLED, TREATED, PRIMED AND INSTALLED NEW FITTING IAW DC8 SRM 53-1-0, 51-1-8, 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C DURING C CHECK INSPECTION, FOUND T BOLT FITTING CORRODED F/S 1178 (C PIT DOOR). REMOVED CORRODED FITTING, DRILLED, TREATED, PRIMED AND INSTALLED NEW FITTING IAW DC8 SRM 53-1-0, 51-1-8, 51-1-20D.