What was found
INSPECTION TYPE:C DURING C CHECK INSPECTION, FOUND CORROSION ON STRAP AT LONGERON 31LT F/S 1165. REMOVED CORRODED SECTION OF STRAP BELOW LONGERON 31LT F/S 1154 TO 1188, DRILLED, TREATED, PRIMED AND INSTALLED NEW SECTION OF STA, REPAIR DOUBLERS AND INTERNAL STRAPS, IAW DAX FAX FILE 97-10-02-011, FAX ACTION NR 346127 AND SKETCH NR5750322 UPS EO DC8-53-2006.