What was found
INSPECTION TYPE:C DURING C CHECK INSPECTION, FOUND LONGERON 32LT SPLICE FITTING CRACKED AT F/S 1350. REMOVED CRACKED SPLICE FITTING, DRILLED, TREATED, PRIMED AND INSTALLED NEW SPLICE FITTING IAW DC8 SRM 53-1-0, 53-2-2, 53-2-0, 51-1-20D, 51-1-8.