What was found
INSPECTION TYPE-D, FOUND CORROSION ON INNER SKIN FS 1690 TO 1680 AT PRODUCTION SPLICE FITTING LONGERON 36. REMOVED FITTING, REMOVED CORROSION FROM SKIN, WITHIN LIMITS IAW DC8 SRM 53-2-0 FIG 1F. TREATED AND PRIMED SKIN IAW DC8 SRM 51-1-8, FOUND CORROSION ON FITTING TO BE OUT OF LIMITS DRILLED NEW FITTING, TREATED PRIMED AND INSTALLED IAW DC8 SRM 51-1-8, 51-1-21, 53-1-0.