What was found
INSPECTION TYPE-, FOUND CORROSION ON FUSELAGE FRAME BOTTOM SIDE AT FS 1100 BL 9LT. REMOVED CORROSION FROM FRAME IAW DC8 SRM 51-1-8, FABRICATED REPAIR DOUBLERS, DRILLED, TREATED, PRIMED AND INSTALLED IAW DC8 SRM 53-2-0, 51-1-8, 51-1-21.