What was found
INSPECTION TYPE-C, WEB BETWEEN FRAMES AT FS 65 AND 70 AND BETWEEN LONGERONS 21L AND 13L HAVE NUMEROUS DOUBLE DRILLED HOLES, OPEN HOLES, AND CRACKS. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT WEB IAW SRM 51-1-21 AND DWG 5597645.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-C, WEB BETWEEN FRAMES AT FS 65 AND 70 AND BETWEEN LONGERONS 21L AND 13L HAVE NUMEROUS DOUBLE DRILLED HOLES, OPEN HOLES, AND CRACKS. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT WEB IAW SRM 51-1-21 AND DWG 5597645.