What was found
INSPECTION TYPE:D DURING D CHECK, INSPECTION FOUND BULGE IN EXTERNAL FUSELAGE SKIN F/S 200 TO 210 AT LONGERON 31RT. FOUND FINGER DOUBLER CORRODED, REMOVED SECTION OF FINGER DOUBLER FROM F/S 190 TO 220, FABRICATED NEW SECTION OF FINGER DOUBLER, DRILLED, TREATED, PRIMED AND INSTALLED IAW DC8 SRM 53-2-0, 51-1-8, 51-1-21, 51-1-20D