What was found
INSPECTION TYPE-C, LONG 21L AT FS 1740 IS CRACKED. REMOVED DAMGED LONGERON SECTION AND FABBED NEW ONE IAW DC8 SRM 53-2-2. SPLICES FABBED IAW DC8 SRM 53-2-2. ALODINED AND PRIMED IAW DC8 SRM 51-1-8, INSTALLED LONG AND SPLICES IAW DC8 SRM 51-1-20D.