What was found
INSPECTION TYPE-C, FLOOR SUPPORT ANGLE AT FS 1740 HAS CORROSION ON BOTTOM FLANGE. REMOVED CORROSION, FABBED HAT SECTIONS, STIFFENERS AND SUPPORTS IAW DC8 SRM 51-3-0 AND DAC DWG 5755032. ALODINED, PRIMED AND INSTALLED COMPONENTS IAW DC8 SRM 51-1-8, 51-1-20D AND DAC DWG 5755032.