What was found
INSPECTION TYPE-SI, CORROSION (C53-224-01.05-03) ON NUT PLATE AND FLOORBEAM AT STA 1166, LBL 10, WL 208. REMOVED CORROSION FOUND TO BE OUT OF LIMITS PER SRM 53-10-01. REPAIRED FLOORBEAM PER SRM 53-10-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-SI, CORROSION (C53-224-01.05-03) ON NUT PLATE AND FLOORBEAM AT STA 1166, LBL 10, WL 208. REMOVED CORROSION FOUND TO BE OUT OF LIMITS PER SRM 53-10-01. REPAIRED FLOORBEAM PER SRM 53-10-8.