What was found
INSPECTION TYPE-SI, WHILE CLOSING FLOOR ON CARD 656802 FOUND CORROSION ON SKIN AT BS 1090 AT STR 28R. REMOVED CORROSION IAW SRM 51-10-6 REWORK OUT OF LIMITS IAW SRM 53-30-1. REPAIRED SKIN AT STA 1090 STR 28R IAW SRM 53-30-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-SI, WHILE CLOSING FLOOR ON CARD 656802 FOUND CORROSION ON SKIN AT BS 1090 AT STR 28R. REMOVED CORROSION IAW SRM 51-10-6 REWORK OUT OF LIMITS IAW SRM 53-30-1. REPAIRED SKIN AT STA 1090 STR 28R IAW SRM 53-30-3.