As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE-SI, NR 7 FLAP TRACK FWD ATTACH FITTING IS CORRODED AT AFT BOLT HOLES FLAP TRACK FWD ATTACH POINT BUSHING HAS MIGRATED. ALSO, FWD HARDWARE REQUIRES REPLACEMENT I/B AND O/B AT RADIUS BLOCKS. REPLACED NR 7 FLAP TRACK FITTING IAW SRM 51-10-1 WILL BE INSTALLED ON TC C57-581-04-4D.