What was found
INSPECTION TYPE:SI CORROSION (C57-581-06.00-03) NR 2 T/E FLAP TRACK CENTER AFT ATTACH MOUNT BOLT HOLE CORRODED. REMOVED CORRODED MOUNT ROUTED TO MACHINE SHOP FOR REWORK PER ER NR 98-2214, REINSTALL AFTER REWORK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SI CORROSION (C57-581-06.00-03) NR 2 T/E FLAP TRACK CENTER AFT ATTACH MOUNT BOLT HOLE CORRODED. REMOVED CORRODED MOUNT ROUTED TO MACHINE SHOP FOR REWORK PER ER NR 98-2214, REINSTALL AFTER REWORK.