What was found
INSPECTION TYPE-C, LT ELEVATOR HAS CRACKED LUGS AT NR 3 HINGE POINT AT ES 66.5. REPAIR CARRIED OUT IAW SRS ENGINEERING ORDER 98-08-001, UPS FILE NUMBER 727-55-0366 AND BOEING SERVICE BULLETIN 727-55-53 REV 3FIGURE 6 AND DRAWING NUMBER 65-68883.