What was found
INSPECTION TYPE-C WHILE WORKING EO#B727-5310-5474B, FOUND CORROSION ON BS 740 FORGING AFT FLANGE COMMON TO FLOORBEAM WL 206 LBL 63. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. REPLACED FORGING IAW EO B727-5310-7477, ER 98-2312.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-C WHILE WORKING EO#B727-5310-5474B, FOUND CORROSION ON BS 740 FORGING AFT FLANGE COMMON TO FLOORBEAM WL 206 LBL 63. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. REPLACED FORGING IAW EO B727-5310-7477, ER 98-2312.