What was found
INSPECTION TYPE:SI BONDED DOUBLER ON TOP SURFACE OF NLG (DOGHOUSE) IS CRACKED AT BS 305 LBL 2 WI L181. REPLACED DOUBLER 16.5 BY 24.5 LBL 14 TO RBL 14 PER 727 SRM 51-40-2, 51-30-2, 51-40-2. BONDED PER BAC5514-551 AND 5514-5101 AND DRAWING 65-18417 AND REPLACED STIFFENER BS 306 LBL 15 TO RBL 15 DUE TO OUT OF LIMITS CORROSION.