What was found
INSPECTION TYPE:D/CK, AFT PIT BOTTOM OF CABIN FLOOR CORRODED 4 PLACES, BTL 12 L, 34R, 12R, AND 34R, STA 1240. CUT OUT DAMAGED IAW DC8 SRM 53 2 3 FIG 10, FABBED DOUBLERS FILLER, REPAIRED ANGLE AND INSTALLED IAW DC8 SRM 53 2 3 FIG 10, DC8 SRM 51 1 21, 51 1 20D. ALODINED AND PRIMED AS REQUIRED IAW DC8 SRM 51 1 8.