What was found
INSPECTION TYPE-C, NR 1 PIT AT STA 600 TO 620 STR 31L SPLICE FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW SRM 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-C, NR 1 PIT AT STA 600 TO 620 STR 31L SPLICE FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW SRM 51-1-20D.