What was found
INSPECTION TYPE:C FWD ACC COMP AT STA 660 BELOW STR 21R, FRAME HAS A 3 INCH CRACK NEAR RADIUS. REMOVED AND REPLACED FRAME SECTION IAW DWG 364688 AND SRM 51-1 20-D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C FWD ACC COMP AT STA 660 BELOW STR 21R, FRAME HAS A 3 INCH CRACK NEAR RADIUS. REMOVED AND REPLACED FRAME SECTION IAW DWG 364688 AND SRM 51-1 20-D.