What was found
INSPECTION TYPE-C, FLOORBEAM ATTACH ANGLE AT STA 780 HAS HEAVY CORROSION AND IS CRACKED. REMOVED AND REPLACED ATTACH ANGLE AT STA 780 RBL 45 TO 69 IAW DWG 3643111 AND SRM 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-C, FLOORBEAM ATTACH ANGLE AT STA 780 HAS HEAVY CORROSION AND IS CRACKED. REMOVED AND REPLACED ATTACH ANGLE AT STA 780 RBL 45 TO 69 IAW DWG 3643111 AND SRM 51-1-20D.