As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C/CK INTERIOR AFT 6 FUSELAGE FLOOR STIFFENER HAS CORROSION ON UNDERSIDE AT STATION 1723 LONGERON 34 RIGHT. REMOVED CORROSION, FOUND OUT OF LIMITS IAW DC8 SRM 53 2 0. FABRICATED WEB IAW DOUGLAS DRAWING 5755032 ALODINED AND PRIMED IAW DC8 SRM 5 1 1 8. INSTALLED WEB IAW DC8 SRM 51 1 20D.