What was found
INSPECTION TYPE:C+S2 RW UPPER INBD AFT SKIN PANEL AT APPROX STA XCW 69.500 IS CRACKED. CUT ATTACHMENT ANGLE TO FWD END OF CRACK, BLENDED AREA OF CRACK IAW DC8 SRM 57-20-0 FIG 7 FOUND TO BE WITHIN LIMITS, PERFORMED HFEC IAW MIL-STD-271F. FOUND NO CRACKS AFTER BLENDING. ALODINED AND PRIMED BLENDED AREA IAW DC8 SRM 51-1-8. FABRICATED ANGLE SPLICE IAW DC8 SRM 53- 20-0. ALODINED AND PRIMED IAW DC8 SRM 51-1-8. INSTALLED SPLICE IAW.