What was found
INSPECTION TYPE:C+S2 CABIN-STA 702 X=69 (CUSP) AT FLOORBEAM ATTACH FITTING CRACKED. REMOVED OLD FITTING DRILLED UP NEW FITTING IAW DC8 SRM 51-1-24. INSTALLED FITTING IAW DC8 SRM 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.