As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C+S2 IN NR 3 MAIN TANK ON INBD SIDE AT APPROX STA XRS 66 TO APPROX XRS 61 LOWER STRINGER NR 51 IS CRACKED ON THE AFT SIDE. REMOVED END FITTING IAW DAC DWG 3704841 PART NR 3704841-501. DRILLED NEW FITTING IAW DC8 SRM 51-3-2. ALODINED AND PRIMED IAW DC8 SRM 51-1-8. INSTALLED FITTING IAW DC8 SRM 51-1-20D.