What was found
INSPECTION TYPE:C/CK COMPLIED WITH FWD BULKHEAD VIEWS FROM CABIN FLOOR STATION 683 X= -2 3 TOP OF VERTICAL STIFFENER BRACKET CRACKED. MATERIAL ID 2024-0 IAW DWG 5773275, HEAT TREATED 2024-0 TO 2024 T4, .100 IAW TPS- 1003 FABRICATED IAW DC8 SRM 51-1-4 AND 51-1-24, ALODINED AND PRIMED IAW DC8 SRM 51-1-8, INSTALLED IAW DC8 SRM 51-1-20D.