What was found
INSPECTION TYPE:C STA 1290 AT STR 21L, THE FRAME TO CUSP TIE FITTING IS CRACKED. REMOVED, FABRICATED AND REPLACED FITTING IAW DWG 975584 AND SRM 5 1-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C STA 1290 AT STR 21L, THE FRAME TO CUSP TIE FITTING IS CRACKED. REMOVED, FABRICATED AND REPLACED FITTING IAW DWG 975584 AND SRM 5 1-1-20D.