What was found
INSPECTION TYPE-N/A, NR 3 ENG FLAMED OUT IN CRUISE FLT AT FL 350 ON ATTEMPTED RE-IGT, EGT CLIMBED RAPIDLY TO 900 DEG, SHUT DOWN ENG. FOB AT TIME WAS 50.0 WITH 12,750 LBS IN NR 3 MAIN NORMAL CONFIG. REPLACED NR 3 ENG MEC PER MM-73-20-01, T/C 1037/1038 SYSTEM LEAK AND OPS CHK OK. (P/N 8063-211) OFF, (P/N 8063-212) ON, (S/N WYG34934) OFF, (S/N WYG35140) ON.