What was found
INSPECTION TYPE:C2 WW PRESS PNL AREA, STA 980 AND XCW 64L FITTING IS CRACKED. REMOVED CRACKED FITTING, FITTING PN NR 4647365-1, FABBED ON NR 50004 LOCATED AND DRILLED IAW DC8 SRM 51-1-24. INSTALLED NEW FITTING IAW DC8 SRM 51-1-20D AND 51-1-17. ALODINED AND PRIMED FITTING MATING SURFACES IAW DC8 SRM 51-1-8.