What was found
INSPECTION TYPE:C, CORROSION (C53-111-03.00-01) ON SHEER TIE IN TRUNNION TORQUE BOX AT BS 306 RBL 18 WL 148. REMOVED CORROSION, OUT OF LIMITS. FABRICATED AND INSTALLED REPAIR PARTS IAW SRM 53-10-4. INSTALLED LEVELING COMPOUND IAW SRM 51-20-4.