What was found
INSPECTION TYPE-C, NR 1 FLAP TRACK FWD ATTACH FITTING OUTBD AFT SPACER CRACKED. BOLT REMOVED AND NEW SPACER, BOLT, WASHER AND LOCKNUT INSTALLED IAW SRM 51-30-2 AND MM 20-80-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-C, NR 1 FLAP TRACK FWD ATTACH FITTING OUTBD AFT SPACER CRACKED. BOLT REMOVED AND NEW SPACER, BOLT, WASHER AND LOCKNUT INSTALLED IAW SRM 51-30-2 AND MM 20-80-01.