What was found
INSPECTION TYPE:SI, CORROSION (C53-224-01.05-01) ON BS 380 FLOORBEAM LBL 55 TO LBL 46 WL 208. CUT OUT DAMAGED FLOORBEAM, FABRICATED REPAIR PARTS AND INSTALLED REPAIR PARTS IAW SRM 53-10-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SI, CORROSION (C53-224-01.05-01) ON BS 380 FLOORBEAM LBL 55 TO LBL 46 WL 208. CUT OUT DAMAGED FLOORBEAM, FABRICATED REPAIR PARTS AND INSTALLED REPAIR PARTS IAW SRM 53-10-8.