What was found
INSPECTION TYPE:SI, DENTED I/B FLANGE ON FRAME AT BS 680, LBL 34, STR 24 IN FWD CARGO BAY. THE DENT ON FRAME OUT OF LIMITS PER SRM 53-10-1. REMOVED DAMAGED SECTION, FABRICATED REPAIR PARTS, ALODINED AND PRIMED THE REPAIR PARTS. INSTALLED REPAIR PARTS, ALL WORK ACCOMPLISHED PER SRM 51-40-3, 51-20-1 AND MM 51-20-21.