What was found
INSPECTION TYPE: C & SI, LIGHT SURFACE CORROSION ON NR 1 FLAP TRACK ATTACH FITTING ON I/B AND O/ B FACES. CORROSION REMOVED IAW SRM 51-10-06, REPAIR CARRIED OUT IAW SMRO EO 99-14-002 UPS ENGINEERING NR 727-57-2074.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C & SI, LIGHT SURFACE CORROSION ON NR 1 FLAP TRACK ATTACH FITTING ON I/B AND O/ B FACES. CORROSION REMOVED IAW SRM 51-10-06, REPAIR CARRIED OUT IAW SMRO EO 99-14-002 UPS ENGINEERING NR 727-57-2074.